EcoFlow DELTA 2 Max vs EcoFlow DELTA 3 1500

Technical comparison · Home backup

In brief

Two expandable EcoFlow units with the same five-year warranty: the DELTA 2 Max has more capacity, more solar input and more power, the DELTA 3 1500 powers loads without a pause in a blackout. The choice depends on how much that pause matters; manufacturer-declared values.

Parameter
In brief
Nominal capacity 2.048 kWh 1.536 kWh
Continuous output 2400 W 1800 W
Peak output 4800 W 3600 W
Cell chemistry LFP (lithium iron phosphate) LFP (lithium iron phosphate)
Cost per kWh 585.45 €/kWh 845.7 €/kWh
List price 1199 € 1299 €
Weight 23 kg —
Dimensions (W×D×H) — 21.3 × 39.8 × 28.15 cm
Outlets
AC outlets Yes (×4) Yes (×4)
How long it lasts
Battery life cycles 1825 cicli 1825 cicli
The limit that runs out first anni di garanzia anni di garanzia
Rated cycles 3000 cicli 3000 cicli
Capacity at end of cycle life 80 % 70 %
Warranty 5 anni 5 anni
The numbers
Cost of stored energy 0.321 €/kWh 0.463 €/kWh
Energy density 89 Wh/kg —
Power-to-capacity ratio 1.17 C 1.17 C
Identity
Use tier F2 — Room-sized (1–3 kWh) F2 — Room-sized (1–3 kWh)
Price
Price — 1299 €
Universal specs
Voltage 220 V —
Category specs
Expandable Yes Yes
Maximum expanded capacity 6.144 kWh 5.5 kWh
Fastest USB-C 100 W 100 W
Maximum charge power 2.4 kW 1.5 kW
0–80% charge time 53 min 60 min
Maximum solar input 1000 W 500 W
Backup power EPS (brief interruption) UPS
Switchover time 20 ms 15 ms
Ingress protection — IP54
Mounting Portable Portable
Minimum temperature -10 °C —
Maximum temperature 45 °C —
Noise level — 45 dB

The differences that matter

  • Solar input 1000 W vs 500 W → the DELTA 2 Max takes twice the panels.
  • Grid charging 2.4 kW vs 1.5 kW, 0 to 80% in 53 minutes vs 60 → the 2 Max is ready again sooner after an outage.
  • Power cut: EPS vs UPS → the 2 Max has a short pause, the 3 1500 does not.
  • Continuous output 2400 W vs 1800 W → loads between 1800 and 2400 W run only on the 2 Max.

Which one to choose

Choose EcoFlow DELTA 2 Max if…

you want more energy and more solar: 2.05 kWh against 1.54, up to 6.14 kWh with expansions, and 1000 W of panels with grid charging at 2.4 kW. In a power cut the switch to battery has a short 20 ms pause (EPS).

See the EcoFlow DELTA 2 Max sheet →

Choose EcoFlow DELTA 3 1500 if…

the connected device must not notice the power cut: switchover takes 15 ms with no interruption (UPS), and protection is IP54. You give up 500 W of solar input, 600 W of continuous output and grid charging above 1.5 kW; the fan reaches 45 dB.

See the EcoFlow DELTA 3 1500 sheet →