BYD Battery-Box Premium HVS 10.2 vs RCT Power Battery 5.7

Technical comparison · High voltage

In brief

The BYD offers 10.24 kWh usable and grows to 38.4 kWh with expansion, the RCT 5.18 kWh; but before size comes the inverter: the RCT is meant for RCT Power Storage DC inverters, the BYD for sixteen brands. All figures are manufacturer-declared values.

Parameter
In brief
Usable capacity 10.24 kWh 5.18 kWh
Cell chemistry LFP (lithium iron phosphate) LFP (lithium iron phosphate)
Weight 167 kg 78 kg
Dimensions (W×D×H) 58.5 × 29.8 × 122.8 cm 34 × 34 × 83 cm
How long it lasts
Battery life cycles 3010 cicli 3650 cicli
The limit that runs out first energia garantita anni di garanzia
Rated cycles 3650 cicli —
Warranty 10 anni 10 anni
Guaranteed throughput 30.82 MWh —
Guaranteed remaining capacity 60 % 80 %
The numbers
Energy density 61.3 Wh/kg 66.4 Wh/kg
Identity
Use tier F4 — House-sized (8–20 kWh) F3 — Flat-sized (3–8 kWh)
Category specs
Depth of discharge 100 % 90 %
Expandable Yes Yes
Maximum expanded capacity 38.4 kWh —
Battery voltage 409.6 V 230 V
Declared compatible inverters Sedici marchi nell'elenco ufficiale: Fronius, GoodWe, Viessmann, KOSTAL, SMA, Sungrow, GE, KACO, KACO NH, Ingeteam, Solis, Canadian Solar, Deye, Solplanet, Western CO, Sosen. Per ciascun modello l'elenco dà il numero di moduli ammessi e la versione minima del firmware. RCT Power Storage DC (6.0/8.0/10.0 LAN, 12.0): intervallo di tensione lato batteria 120-600 V dichiarato dall'inverter, entro cui rientra questa taglia (230 V nominali, 180-260 V di range).
Round-trip efficiency 96 % —
Standby consumption — 5 W
Ingress protection IP55 ip42
Mounting Floor standing Floor standing
Minimum temperature -10 °C 5 °C
Maximum temperature 50 °C 40 °C
Works without internet Fully —
Local control Local network None
Open protocols CAN bus —
Remote updates Can be disabled —
App required for setup Yes —
Declared standards CE, UN 38.3, IEC 62619, VDE 2510-50 CE, UN 38.3, IEC 62619

The differences that matter

  • 10.24 vs 5.18 kWh usable → the BYD has twice the energy and can reach 38.4 kWh with expansion; the RCT is an apartment-size unit.
  • Inverters: sixteen brands vs RCT Power Storage DC → with any other inverter, only the BYD is an option (if your model is listed).
  • Guaranteed capacity at end of warranty: 60 % vs 80 % → after ten years the RCT declares it keeps more capacity.
  • IP55, -10 to 50 °C vs IP42, 5 to 40 °C → the BYD tolerates colder or more exposed rooms; the RCT needs an indoor room above 5 °C.

Which one to choose

Choose BYD Battery-Box Premium HVS 10.2 if…

your inverter is not an RCT and you want to add modules later. It works fully without internet, is controlled over the local network and remote updates can be disabled. The compromise is bulk: it is a column over 120 cm tall and weighs 167 kg.

See the BYD Battery-Box Premium HVS 10.2 sheet →

Choose RCT Power Battery 5.7 if…

your inverter is an RCT Power Storage DC and space is tight: 78 kg and 34 × 34 × 83 cm. The compromise is the environment: IP42 and a 5 °C minimum call for an indoor room that does not freeze, and there is no local control.

See the RCT Power Battery 5.7 sheet →

Where to buy